Construction | ||
Inner Conductor Material & Diameter | Smooth Copper Tube | Ø13.00mm |
Dielectric Material & Diameter | Physical Foam Polyethylene | Ø32.80mm |
Outer Conductor Material & Diameter | Corrugated Copper Tube | |
Jacket Material & Diameter | Black PE | Ø38.60mm |
Mechanical and Electrical Characteristics | |
Impedance | 50±1.0 Ohms |
Capacitance | 76(pF/m) |
Velocity Factor | 88% |
Maximum Operating Frequency | ≤3.7 GHz |
Peak Voltage | ≤4.3kV |
Insulation Resistance | 5000 MΩ.km |
VSWR | ≤1.13@0.8-2.7GHz |
Minimum Bending Radius | Single Bending: 150 mm, Repeated Bending: 380 mm |
Tensile Strength | 2900 N |
No. of Bends Minimum (Typical) | 15 (40) |
Temperature Range | Installation Temperature: -40℃ to +60℃, Operating Temperature: -55℃ to +85℃ |
Attenuation[@68°F. (20°C)] | ||
Frequency(MHz) | Power Rating(kW) | Maximum(dB/100m) |
100 | 12.52 | 0.80 |
400 | 5.65 | 1.72 |
450 | 5.52 | 1.78 |
700 | 4.25 | 2.33 |
800 | 4.03 | 2.47 |
900 | 3.73 | 2.64 |
1000 | 3.50 | 2.80 |
1500 | 2.80 | 3.56 |
1800 | 2.50 | 3.96 |
2000 | 2.31 | 4.23 |
2200 | 2.19 | 4.48 |
2600 | 1.95 | 4.96 |
3600 | 1.57 | 6.17 |